Fluke 4025180 190 Series II Colored ScopeMeter *DISCONTINUED*

    By Fluke | Mfr#: 4025180 | Tiger#: TS52119
    • Fluke 190 Series II Colored ScopeMeter FLU4025180-
    • Fluke 190 Series II Colored ScopeMeter FLU4025180-
    • Fluke 190 Series II Colored ScopeMeter FLU4025180-
    • Fluke 190 Series II Colored ScopeMeter FLU4025180-

    Highlights

    • Choice of 16 packages
    • Rating: CAT III 1000 V and CAT IV 600 V
    • Connect-and-View feature for fast and complex signals
    • ScopeRecord Roll mode
    • TrendPlot paperless recorder with deep memory
    • Display: 6-inch LCD with backlight
    • IP51 dustproof and water droplet resistant
    • Battery life up to 7 hours
    More Product Details What's Included
    $3699.99
    • Product Options
    Availability:Out Of Stock
    Ships Out Within: Discontinued
    Tiger Supplies no longer carries this item

    Overview for Fluke 4025180 190 Series II Colored ScopeMeter


    Built for technicians and plant maintenance engineers, the Fluke 190 Series II Colored ScopeMeter provides multiple functions of a bench oscilloscope and a multimeter for troubleshooting and onsite inspections. It features four independent floating isolated inputs with power up to 1,000 volts. For safety purposes, the Fluke 190 Series II is CAT III 1000 V/CAT IV 600 V rated for industrial environments.

    This Fluke ScopeMeter has the Connect-and-View feature for fast and complex signals. For low-frequency signal analysis, it comes with the ScopeRecord Roll mode that provides 30,000 points per channel. Also, it makes data recording easier with the TrendPlot paperless recorder with deep memory which is specially made for a long duration, automatic measurements.

    With an IP51 rating, the 190 Series II is protected from dust and water droplets. It uses a rechargeable Li-ion battery that powers the device up to seven hours which is ready for any long day's work. For easy data viewing, this colored ScopeMeter features a large six-inch LCD display with backlight. As an addition, it adheres to safety compliance standards - EN61010-1-2002, Pollution Degree 2, CAN/CSA C22.2 and ANSI/ISA.

    Configuration Options

    The Fluke 190 Series II Colored ScopeMeter has 16 available packages that have varying bandwidth and number of channels. It also has two versions - American version and the universal version. Please choose from the drop-down menu above.

    • 4025180: Fluke 190-062/AM 60MHz Colored ScopeMeter, 2 Channels
    • 4025253: Fluke 190-062/AM/S 60MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software

    This package includes C290 Hard-shell carrying case, SW90W FlukeView for ScopeMeter test tool, and the Windows software. The SW90W is a ScopeMeter software helps in storing and saving waveforms, gathering measurement data, and performing waveform analysis.

    • 4025334: Fluke 190-102/AM 100MHz Colored ScopeMeter, 2 Channels 
    • 4025408: Fluke 190-102/AM/S 100MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software
    • 3894569: Fluke 190-104/AM 100MHz Colored ScopeMeter, 4 Channels
    • 3894639: Fluke 190-104/AM/S 100MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software
    • 4025485: Fluke 190-202/AM 200MHz Colored ScopeMeter, 2 Channels 
    • 4025579: Fluke 190-202/AM/S 200MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software 
    • 3894427: Fluke 190-204/AM 200MHz Colored ScopeMeter, 4 Channels 
    • 3894494: Fluke 190-204/AM/S 200MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software
    • 4025645: Fluke 190-502/AM 500MHz Colored ScopeMeter, 2 Channels
    • 4025719: Fluke 190-502/AM/S 500MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software 
    • 4419882: Fluke 190-504/AM 500MHz Colored ScopeMeter, 4 Channels
    • 4419952: Fluke 190-504/AM/S 500MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software 
    • 4419929: Fluke 190-504/UN 500MHz Colored ScopeMeter, 4 Channels (Universal Version) 
    • 4419990: Fluke 190-504/UN/S 500MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software (Universal Version)


    Model #


    Fluke 190-062


    Fluke 190-10X


    Fluke 190-20X


    Fluke 190-50X


    Number of Channels


    2


    190-102:
    2
    190-104: 4


    190-202: 
    2
    190-204: 4


    190-502: 
    2
    190-504: 4


    Bandwidth


    60 MHz


    100 MHz


    200 MHz


    500 MHz


    Rise Time (Nanosecond)


    5.8 ns


    3.5 ns


    1.7 ns


    0.7 ns


    Number of Scope Inputs


    2 input channels plus external trigger


    190-102: 
    2 input channels plus external trigger

    190-104: 4 input channels


    190-202: 
    2 input channels plus external trigger

    190-204: 4 input channels


    190-502: 
    2 input channels plus external trigger

    190-504: 4 input channels


    Maximum Real-Time Sample Rate (sampled simultaneously)


    625 MS/s for each channel


    1.25 GS/s for each channel


    190-202: 
    2.5 GS/s (2ch)

    190-204: 
    2.5 GS/s (2ch); 1.25 GS/s (4ch)


    190-502: 
    5 GS/s (single channel) or 2.5 GS/s (on 2ch)

    190-504: 
    5 GS/s (single channel) or 1.25 GS/s per channel


    Meter Inputs


    Via 4 mm banana inputs, fully isolated from scope inputs and scope ground


    190-102: 
    Via 4 mm banana inputs, fully isolated from scope inputs and scope ground

    190-104:  Via BNC scope inputs


    190-202: 
    Via 4 mm banana inputs, fully isolated from scope inputs and scope ground

    190-204:  Via BNC scope inputs


    190-502: 
    Via 4 mm banana inputs, fully isolated from scope inputs and scope ground

    190-504: 
    Via BNC scope inputs


    Number of Readings


    One at a time


    190-102: 
    One at a time

    109-104:  Up to 4 simultaneously


    190-202: 
    One at a time

    190-204: Up to 4 simultaneously


    190-502: 
    One at a time

    190-504: Up to 4 simultaneously


    Maximum Resolution


    5,000 counts


    190-102: 
    5,000 counts

    190-104:  999 counts


    190-202: 
    5,000 counts

    190-204: 999 counts


    190-502: 
    5,000 counts

    190-504: 999 counts


    Voltage DC Accuracy


    ± (0.5 % + 5 counts)


    190-102: 
    ± (0.5 % + 5 counts)

    190-104:  ± (1.5 % + 5 counts)


    190-202: 
    ± (0.5 % + 5 counts)

    190-204: ± (1.5 % + 5 counts)


    190-502: 
    ± (0.5 % + 5 counts)

    190-504:  ± (1.5 % + 5 counts)


    Includes


    190-062 Americas Package

    • DMM/Ext.input
    • 2 Channels


    190-062 Americas Package with FlukeView

    • DMM/Ext.input
    • 2 Channels
    • C290 Hard-shell carrying case
    • SW90W FlukeView for ScopeMeter test tool
    • Windows software


    190-102 Americas Package

    • DMM/Ext.input
    • 2 Channels


    190-102 Americas Package with FlukeView

    • DMM/Ext.input
    • 2 Channels
    • C290 Hard-shell carrying case
    • SW90W FlukeView for ScopeMeter test tool
    • Windows software


    190-104 Americas Package

    • DMM/Ext.input
    • 4 Channels


    190-104 Americas Package with FlukeView

    • DMM/Ext.input
    • 4 Channels
    • C290 Hard-shell carrying case
    • SW90W FlukeView for ScopeMeter test tool
    • Windows software


    190-202 Americas Package

    • DMM/Ext.input
    • 2 Channels


    190-202 Americas Package with FlukeView

    • DMM/Ext.input
    • 2 Channels
    • C290 Hard-shell carrying case
    • SW90W FlukeView for ScopeMeter test tool
    • Windows software


    190-204 Americas Package

    • DMM/Ext.input
    • 4 Channels


    190-204 Americas Package with FlukeView

    • DMM/Ext.input
    • 4 Channels
    • C290 Hard-shell carrying case
    • SW90W FlukeView for ScopeMeter test tool
    • Windows software


    190-502 Americas Package

    • DMM/Ext.input
    • 2 Channels


    190-502 Americas Package with FlukeView

    • DMM/Ext.input
    • 2 Channels
    • C290 Hard-shell case
    • SW90W FlukeView for ScopeMeter test tool
    • Windows software


    190-504 Americas Package

    • DMM/Ext.input
    • 4 Channels
    • Power adapter, BC190/813 120V ±10%


    190-504 Americas Package with FlukeView

    • DMM/Ext.input
    • 4 Channels
    • C290 Hard-shell case
    • SW90W FlukeView for ScopeMeter
    • Windows software
    • Power adapter, BC190/813 120V ±10%


    190-504 Universal Package

    • DMM/Ext.input
    • 4 Channels
    • Power adapter, BC190/820 100V to 240V ±10%


    190-504 Universal Package with FlukeView

    • DMM/Ext.input
    • 4 Channels
    • C290 Hard-shell case
    • SW90W FlukeView for ScopeMeter
    • Windows software
    • Power adapter, BC190/820 100V to 240V ±10%