Built for technicians and plant maintenance engineers, the Fluke 190 Series II Colored ScopeMeter provides multiple functions of a bench oscilloscope and a multimeter for troubleshooting and onsite inspections. It features four independent floating isolated inputs with power up to 1,000 volts. For safety purposes, the Fluke 190 Series II is CAT III 1000 V/CAT IV 600 V rated for industrial environments.
This Fluke ScopeMeter has the Connect-and-View feature for fast and complex signals. For low-frequency signal analysis, it comes with the ScopeRecord Roll mode that provides 30,000 points per channel. Also, it makes data recording easier with the TrendPlot paperless recorder with deep memory which is specially made for a long duration, automatic measurements.
With an IP51 rating, the 190 Series II is protected from dust and water droplets. It uses a rechargeable Li-ion battery that powers the device up to seven hours which is ready for any long day's work. For easy data viewing, this colored ScopeMeter features a large six-inch LCD display with backlight. As an addition, it adheres to safety compliance standards - EN61010-1-2002, Pollution Degree 2, CAN/CSA C22.2 and ANSI/ISA.
Configuration Options
The Fluke 190 Series II Colored ScopeMeter has 16 available packages that have varying bandwidth and number of channels. It also has two versions - American version and the universal version. Please choose from the drop-down menu above.
- 4025180: Fluke 190-062/AM 60MHz Colored ScopeMeter, 2 Channels
- 4025253: Fluke 190-062/AM/S 60MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software
This package includes C290 Hard-shell carrying case, SW90W FlukeView for ScopeMeter test tool, and the Windows software. The SW90W is a ScopeMeter software helps in storing and saving waveforms, gathering measurement data, and performing waveform analysis.
- 4025334: Fluke 190-102/AM 100MHz Colored ScopeMeter, 2 Channels
- 4025408: Fluke 190-102/AM/S 100MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software
- 3894569: Fluke 190-104/AM 100MHz Colored ScopeMeter, 4 Channels
- 3894639: Fluke 190-104/AM/S 100MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software
- 4025485: Fluke 190-202/AM 200MHz Colored ScopeMeter, 2 Channels
- 4025579: Fluke 190-202/AM/S 200MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software
- 3894427: Fluke 190-204/AM 200MHz Colored ScopeMeter, 4 Channels
- 3894494: Fluke 190-204/AM/S 200MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software
- 4025645: Fluke 190-502/AM 500MHz Colored ScopeMeter, 2 Channels
- 4025719: Fluke 190-502/AM/S 500MHz Colored ScopeMeter, 2 Channels with C290 Hard Case & SW90W Software
- 4419882: Fluke 190-504/AM 500MHz Colored ScopeMeter, 4 Channels
- 4419952: Fluke 190-504/AM/S 500MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software
- 4419929: Fluke 190-504/UN 500MHz Colored ScopeMeter, 4 Channels (Universal Version)
- 4419990: Fluke 190-504/UN/S 500MHz Colored ScopeMeter, 4 Channels with C290 Hard Case & SW90W Software (Universal Version)
Model #
| Fluke 190-062
| Fluke 190-10X
| Fluke 190-20X
| Fluke 190-50X
|
Number of Channels
| 2
| 190-102: 2 190-104: 4
| 190-202: 2 190-204: 4
| 190-502: 2 190-504: 4
|
Bandwidth
| 60 MHz
| 100 MHz
| 200 MHz
| 500 MHz
|
Rise Time (Nanosecond)
| 5.8 ns
| 3.5 ns
| 1.7 ns
| 0.7 ns
|
Number of Scope Inputs
| 2 input channels plus external trigger
| 190-102: 2 input channels plus external trigger
190-104: 4 input channels
| 190-202: 2 input channels plus external trigger
190-204: 4 input channels | 190-502: 2 input channels plus external trigger
190-504: 4 input channels |
Maximum Real-Time Sample Rate (sampled simultaneously)
| 625 MS/s for each channel
| 1.25 GS/s for each channel
| 190-202: 2.5 GS/s (2ch)
190-204: 2.5 GS/s (2ch); 1.25 GS/s (4ch)
| 190-502: 5 GS/s (single channel) or 2.5 GS/s (on 2ch)
190-504: 5 GS/s (single channel) or 1.25 GS/s per channel
|
Meter Inputs
| Via 4 mm banana inputs, fully isolated from scope inputs and scope ground
| 190-102: Via 4 mm banana inputs, fully isolated from scope inputs and scope ground
190-104: Via BNC scope inputs
| 190-202: Via 4 mm banana inputs, fully isolated from scope inputs and scope ground
190-204: Via BNC scope inputs
| 190-502: Via 4 mm banana inputs, fully isolated from scope inputs and scope ground
190-504: Via BNC scope inputs
|
Number of Readings
| One at a time
| 190-102: One at a time
109-104: Up to 4 simultaneously
| 190-202: One at a time
190-204: Up to 4 simultaneously
| 190-502: One at a time
190-504: Up to 4 simultaneously
|
Maximum Resolution
| 5,000 counts
| 190-102: 5,000 counts
190-104: 999 counts
| 190-202: 5,000 counts
190-204: 999 counts
| 190-502: 5,000 counts
190-504: 999 counts
|
Voltage DC Accuracy
| ± (0.5 % + 5 counts)
| 190-102: ± (0.5 % + 5 counts)
190-104: ± (1.5 % + 5 counts)
| 190-202: ± (0.5 % + 5 counts)
190-204: ± (1.5 % + 5 counts)
| 190-502: ± (0.5 % + 5 counts)
190-504: ± (1.5 % + 5 counts)
|
Includes
| 190-062 Americas Package
190-062 Americas Package with FlukeView
- DMM/Ext.input
- 2 Channels
- C290 Hard-shell carrying case
- SW90W FlukeView for ScopeMeter test tool
- Windows software
| 190-102 Americas Package
190-102 Americas Package with FlukeView
- DMM/Ext.input
- 2 Channels
- C290 Hard-shell carrying case
- SW90W FlukeView for ScopeMeter test tool
- Windows software
190-104 Americas Package
190-104 Americas Package with FlukeView
- DMM/Ext.input
- 4 Channels
- C290 Hard-shell carrying case
- SW90W FlukeView for ScopeMeter test tool
- Windows software
| 190-202 Americas Package
190-202 Americas Package with FlukeView
- DMM/Ext.input
- 2 Channels
- C290 Hard-shell carrying case
- SW90W FlukeView for ScopeMeter test tool
- Windows software
190-204 Americas Package
190-204 Americas Package with FlukeView
- DMM/Ext.input
- 4 Channels
- C290 Hard-shell carrying case
- SW90W FlukeView for ScopeMeter test tool
- Windows software
| 190-502 Americas Package
190-502 Americas Package with FlukeView
- DMM/Ext.input
- 2 Channels
- C290 Hard-shell case
- SW90W FlukeView for ScopeMeter test tool
- Windows software
190-504 Americas Package
- DMM/Ext.input
- 4 Channels
- Power adapter, BC190/813 120V ±10%
190-504 Americas Package with FlukeView
- DMM/Ext.input
- 4 Channels
- C290 Hard-shell case
- SW90W FlukeView for ScopeMeter
- Windows software
- Power adapter, BC190/813 120V ±10%
190-504 Universal Package
- DMM/Ext.input
- 4 Channels
- Power adapter, BC190/820 100V to 240V ±10%
190-504 Universal Package with FlukeView
- DMM/Ext.input
- 4 Channels
- C290 Hard-shell case
- SW90W FlukeView for ScopeMeter
- Windows software
- Power adapter, BC190/820 100V to 240V ±10%
|